Industrial Control Wiring Harnesses | Woren

  • brenda.liang@kshuaren.com
  • +86-138-6264-1537

Industrial Control Wiring Harnesses

We provide high-quality industrial control wiring harness solutions for automation equipment, control systems, and industrial machinery. With precision manufacturing and strict quality control, our products ensure stable signal transmission, reliable connectivity, and long-lasting performance in demanding industrial environments.

Product Display

OBD Cable
OBD Cable
Power Supply Wiring Harness
Power Supply Wiring Harness
USB 3.0 Wiring Harness
USB 3.0 Wiring Harness
USB Charging Cable Adapters
USB Charging Cable Adapters
USB Charging Cables
USB Charging Cables
USB 3.0 Cable
USB 3.0 Cable

Automotive wire parameters

German standard automotive wire
Japanese standard wire
FLRY-A type
Nominal cross-sectional area
mm²
Conductor Insulation Finished outer diameter
Number of conductors Maximum diameter of a single
conductor
Calculated cross-sectional
area
mm²
Maximum outer diameter mm Max. resistance of bare copper at
20°C (mΩ/m)
Max. resistance of tinned copper at
20°C (mΩ/m)
Minimum thickness (mm) Minimum outer diameter (mm) Maximum outer diameter (mm)
Max Min
0.22 7 0.21 0.219 0.202 0.7 84.8 86.5 0.2 1.1 1.2
0.35 7 0.26 0.355 0.329 0.8 52 54.5 0.2 1.2 1.3
0.5 19 0.19 0.498 0.461 1 37.1 38.2 0.22 1.4 1.6
0.75 19 0.23 0.748 0.692 1.2 24.7 25.4 0.24 1.7 1.9
1 19 0.26 0.998 0.925 1.35 18.5 19.1 0.24 1.9 2.1
1.5 19 0.32 1.455 1.345 1.7 12.7 13 0.24 2.2 2.4
2.5 19 0.41 2.43 2.25 2.2 7.6 7.8 0.28 2.7 3
FLRYB-A type
Nominal cross-sectional area
mm²
Conductor Insulation Finished outer diameter
Number of conductors Maximum diameter of a single
conductor
Calculated cross-sectional
area
mm²
Maximum outer diameter mm Max. resistance of bare copper at
20°C (mΩ/m)
Max. resistance of tinned copper at
20°C (mΩ/m)
Minimum thickness (mm) Minimum outer diameter (mm) Maximum outer diameter (mm)
Max Min
0.35 12 0.21 0.355 0.329 0.9 52 54.5 0.2 1.2 1.4
0.5 16 0.21 0.498 0.461 1 37.1 38.2 0.22 1.4 1.6
0.75 24 0.21 0.748 0.692 1.2 24.7 25.4 0.24 1.7 1.7
1 32 0.21 0.998 0.925 1.35 18.5 19.1 0.24 1.9 2.1
1.5 30 0.26 1.455 1.345 1.7 12.7 13 0.24 2.2 2.4
2.5 50 0.26 2.43 2.25 2.2 7.6 7.8 0.28 2.7 3
4 56 0.31 3.93 3.64 2.75 4.7 4.8 0.32 3.4 3.7
6 84 0.31 5.96 5.52 3.3 3.1 3.2 0.32 4 4.3
FLRY-A type
Nominal cross-sectional area
mm²
Conductor Insulation Finished outer diameter
Number of conductors Maximum diameter of a single
conductor
Calculated cross-sectional
area
mm²
Maximum outer diameter mm Max. resistance of bare copper at
20°C (mΩ/m)
Max. resistance of tinned copper at
20°C (mΩ/m)
Minimum thickness (mm) Minimum outer diameter (mm) Maximum outer diameter (mm)
Max Min
0.22 7 0.21 0.219 0.202 0.7 84.8 86.5 0.2 1.1 1.2
0.35 7 0.26 0.355 0.329 0.8 52 54.5 0.2 1.2 1.3
0.5 19 0.19 0.498 0.461 1 37.1 38.2 0.22 1.4 1.6
0.75 19 0.23 0.748 0.692 1.2 24.7 25.4 0.24 1.7 1.9
1 19 0.26 0.998 0.925 1.35 18.5 19.1 0.24 1.9 2.1
1.5 19 0.32 1.455 1.345 1.7 12.7 13 0.24 2.2 2.4
2.5 19 0.41 2.43 2.25 2.2 7.6 7.8 0.28 2.7 3
FLRYB-A type
Nominal cross-sectional area
mm²
Conductor Insulation Finished outer diameter
Number of conductors Maximum diameter of a single
conductor
Calculated cross-sectional
area
mm²
Maximum outer diameter mm Max. resistance of bare copper at
20°C (mΩ/m)
Max. resistance of tinned copper at
20°C (mΩ/m)
Minimum thickness (mm) Minimum outer diameter (mm) Maximum outer diameter (mm)
Max Min
0.35 12 0.21 0.355 0.329 0.9 52 54.5 0.2 1.2 1.4
0.5 16 0.21 0.498 0.461 1 37.1 38.2 0.22 1.4 1.6
0.75 24 0.21 0.748 0.692 1.2 24.7 25.4 0.24 1.7 1.7
1 32 0.21 0.998 0.925 1.35 18.5 19.1 0.24 1.9 2.1
1.5 30 0.26 1.455 1.345 1.7 12.7 13 0.24 2.2 2.4
2.5 50 0.26 2.43 2.25 2.2 7.6 7.8 0.28 2.7 3
4 56 0.31 3.93 3.64 2.75 4.7 4.8 0.32 3.4 3.7
6 84 0.31 5.96 5.52 3.3 3.1 3.2 0.32 4 4.3
Together in Heart
Together in Step — Connect and Win.

    Message:

    Copyright © Kunshan Woren Industrial and Trading Co.,Ltd Powered by Bomin